An Analysis of the Data Obtained Through the Implementation of Atomic Absorption Spectrometry

Profile Picture
Posted by DaniBogdan from the Arts & Entertainment category at 16 Aug 2022 04:29:58 pm.
Thumbs up or down
Share this page:




A multi-step process is required for data analysis when using aas spectrophotometer (AAS). During this phase of the process, it is the user's responsibility to choose the proper method and wavelengths in order to achieve the best results that can be achieved. Before attempting to perform a successful analysis of the AAS data, one of the necessary steps that needs to be taken is to correct the background. Deuterium correction and Zeeman background correction are two of the most common types of typical correction methods; therefore, AAS technology makes extensive use of a variety of these standard correction methods. In addition to that, it is the one that has the most previous experience. In this method, a separate source (a deuterium lamp) with a broad emission is utilized in order to measure the background absorption across the entire width of the exit slit of the spectrometer. This is done by employing a broad-emitting light source. This method is the least accurate of the three because it requires the use of a separate lamp and is therefore unable to correct for any background that has a structured pattern. Additionally, this method is the least accurate method overall. In addition to this, it can't be used at wavelengths longer than 320 nm because the intensity of the deuterium lamp's emission drops off significantly after this point in the spectrum. This precludes its use at those longer wavelengths.

In order to provide more insight into Zeeman's past, a few minor adjustments have been made.

An alternating magnetic field is applied at the atomizer, which is also referred to as the graphite furnace, while the Zeeman background correction procedure is being carried out.

Finding out the total absorption prior to activating the magnetic field is the first thing that needs to be done. It is necessary to remove the component before carrying out this set of measurements in order to prevent the components from overlapping with the emission profile of the lamp. This overlap can only be avoided by removing the component. Eliminating the component is the only way to stop this from happening. In the process of carrying out this step, one of the tools that is utilized most frequently is a polarizer.

Because both the total and background absorption are measured within the same emission profile of the same lamp, this method has the advantage of being able to correct for any kind of background, including backgrounds with fine structure. This is possible due to the fact that this method measures both the total and background absorption simultaneously. If the magnetic field also has an effect on the molecule that makes up the background, then it will not be possible to use this process. The magnetic field's origin can be traced back to the background molecule. In addition, the increased power can only originate from a single origin. The process of AAS data analysis and optimization can make use of a number of different methods, including the utilization of an internal standard, the standard addition method, and the standard subtraction method. There are additionally other potential courses of action to take.

Internal standards
In analytical chemistry, all of the samples, the blank, and the calibration standards have exactly the same amount of a substance that is known as an internal standard added to them. This ensures that the results of the analysis are consistent. This guarantees that the conclusions drawn from the analysis are reliable. After that, you can employ this substance in the process of calibrating your apparatus. Both of those processes could have been responsible for the loss of the analyte that was measured.

The internal standard is a compound that is very similar to the chemical species of interest in the samples, but it is not an exact match for those chemical species. This similarity does not mean that the two compounds are identical, however. As a direct consequence of this, the effects of sample preparation should be the same for both the internal standard and the chemical species of interest (relative to the concentration of each species), as this will guarantee that the results are accurate. This should absolutely be the case as a direct consequence of this situation. Gas chromatography and mass spectrometry are two more examples of the types of analyses that fall under this category. The method of quantitative analysis known as standard addition involves adding the standard directly to aliquots of the sample that is being analyzed. This helps ensure that the results of the analysis are accurate. In order to guarantee that the findings of the analysis are reliable, this step is taken. The process in question is also known as "direct addition," another name for the method. In circumstances such as this one, this particular strategy is the one that is implemented. Because of this effect, it is not possible to use the conventional calibration curve method to make a comparison between the analytical signal output of the sample and the standard. This is because the method relies on a linear relationship between the sample and the standard.

The software that is utilized throughout the atomic absorption spectrometer procedure
Not only is it necessary to make use of appropriate instrumentation in order to conduct accurate and precise AAS measurements, but it is also necessary to make use of appropriate software in order to fulfill these requirements. In point of fact, having the appropriate software not only makes it easier to control the instrument, but it also makes it possible to efficiently acquire, manipulate, and interpret data.

The process of managing instruments and data can frequently be made a great deal less complicated by making use of software wizards. This can be the case in a variety of situations. In addition, they are helpful to any user, regardless of the user's level of expertise in the subject matter. This is another advantage of using them. There are a few software wizards that are built right into the instrument, such as the Thermo Scientific SOLAAR wizard that is displayed in figure 3. Other software wizards include:There are even wizards that can perform calculations while also guiding the user through the subsequent steps of the workflow. These wizards can be found in many modern computer programs.